D. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).

Figure 5.3 Minimum Vertical and Maximum Horizontal

Dimensions of Combustibles

Figure 5.4 Combustible Mantel Leg or Wall Projections

(Acceptable on both sides of opening)

Combustible Mantels

Combustible Mantel Legs or Wall Projections

A

B

INTERIOR WALL

TOP VIEW

MANTEL LEG OR WALL PROJECTIONS

FIREPLACE OPENING

If

A

minimum is ____, then

B

maximum is_____.

A

Inches

2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16

Millimeters

62

87

113

138

164

189

B

Inches

1

2

3

4

5

Millimeters

25

51

76

102

127

MEASUREMENTS FROM

TOP EDGE OF THE OPENING

5

10

11

12

2-1/2

13

14

15

16

17

18

19

32

TO CEILING

9

10

11

12

8

7

6

5

4

3

25

18

Note: All
measurements
in inches.

Note: Measurement is taken from top of the opening,
NOT the top of the fi replace.