I. Air Shutter Setting

Air shutter settings should be adjusted by a qualifi ed ser-
vice technician at the time of installation. The air shutter
is set at the factory for minimum vertical vent run. Adjust
air shutter for longer vertical runs.

• Loosen the wing nut.

• Push the air handle in to close the air shutter.

• Pull the air handle out to open the air shutter.

• Tighten the wing nut.

NOTICE: If sooting occurs, provide more air by opening
the air shutter.

Figure 14.14 Fixed Glass Assembly

G. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fi xed glass
assembly with care. Inspect the gasket to ensure it is
undamaged and inspect the glass for cracks, chips or
scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fi replace with glass removed, cracked,

broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

• Pull the four glass assembly latches out of the groove on

the glass frame. Remove glass door from the appliance

(see Figure 14.14).

Replacing Fixed Glass Assembly

• Replace the glass door on the appliance. Pull out and

latch the four glass assembly latches into the groove on
the glass frame.

Air Shutter Settings

NG

LP

Burner

1/8 in.

1/4 in.

H. Install Trim and/or Surround

• Install optional trim kits and/or surrounds using the

instructions included with the accessory.

• Use non-combustible materials to cover the gap between

the sheet rock and the appliance (when applicable to the
model).