Error conditions, Error conditions 56 – HP XP12000 User Manual

Page 54

Advertising
background image

56

HP StorageWorks Disk Array XP Operating System Configuration Guide: HP-UX

Error conditions

Depending on your system configuration, you may be able to view error
messages as follows:

• In Remote Web Console (Status tab)

• In Command View Advanced Edition (“Alerts” panel).

• In Command View (Event History or Event Notification panels).

Error Condition

Recommended Action

The logical devices are not
recognized by the host.

Verify that the READY indicator lights on the disk array are ON.

Verify that fiber cables are correctly installed and firmly connected.

Verify that the target IDs are properly configured. The LUNs for each
TID must start at 0 and continue sequentially without skipping any
numbers.

Verify that the TIDs/WWNs on each bus are unique. Do not install two
devices with the same ID on the same bus.

Recheck the buses for new devices.

Verify that LUSE devices are not intermixed with normal LUNs on the
same port.

Verify that the maximum number of LUSE devices per port has not
been exceeded.

Verify that the disk array host mode is set correctly.

The host does not reboot
properly after hard shutdown.

If you power off the host without executing the shutdown process, wait
three minutes to allow the disk array’s internal timeout process to
purge queued commands. If the host restarts while the disk array is
processing queued commands, the host may not reboot successfully.

Advertising
This manual is related to the following products: