Installation procedure – haier AB482XCAAA AB242XCAAA User Manual

Page 32

Advertising
background image

30

2. Install wire controller

(1) For exposed installation,

use 2 wood screws (accessory).

(2) For recessed installation,

use 2 wood screws (accessory).

Note

Try as far as possible a flat surface for installation. Don't use excessive

force when tightening screws, or lower part might got deformed.

3. Indoor unit wiring

Connect terminals (A,B,C,D) on lower part of wire controller

to terminals (A,

B,C,D) on PCB of indoor unit.

Hint

When make wiring, please keep

a distance between wires and

power supply cord.

Cord kind

Size

Shield wire (4 core) (refer to Hint 3,4)

0.33mm2

Wire size

Use shielede wires for telecommunication
between wire controller and indoor unit;
indoor unit and outdoor unit. Ground the
shield on one side.
Otherwise misoperation because of
noise may occur.
Signal wire is self-provided.

Shielded wire

ground

Lower part of

wire controller

A B

C D

Upper part of

wire controller

wiring from here

Installation Procedure