C. clearances, D. mantel projections – Heat & Glo Fireplace 6100PLUS User Manual

Page 8

Advertising
background image

8

Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05

C. Clearances

1 in. (25 mm) min.
to perpendicular wall

A

3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall

B

48 in.

(1219 mm)

max.

Mantel Leg or

Perpendicular Wall

Top of
Appliance

Drywall

A

B

Figure 3.4

Clearances to Mantel Legs or Wall Projections (Accept-

able on both sides of opening)

0 in.

1/2 in.

(13 mm)

32-7/8 in.

(835 mm)

0 in.

to floor

0 in. to combustibles

in front of the FAF

23-1/2 in.

(597 mm)

38-3/4 in.

(984 mm)

42 in.

(1067 mm)

Figure 3.2

Clearances to Combustibles

Measured from top of fireplace opening (in inches)

3

4

5

6

7

8

9

10

11

12

10-3/4

13-3/4

13-3/4

13-3/4

16-3/4

16-3/4

16-3/4

19-3/4

19-3/4

19-3/4

32-7/8 in. minimum

to ceiling

Figure 3.3

Clearances to Mantels or Other Combustibles Above

Appliance

D. Mantel Projections

Advertising