PIPING INSTALLATION
NOTE: The most effective means for preventing deterioration from accelerated corrosion
due to galvanic and stray current is the installation of dielectric fittings/unions. The
installation of these fittings is the responsibility of the installing contractor.

1. Connect the cold water inlet and hot water outlet to the appropriate connections as

shown; refer to installation diagram.

2. Provide a shut off valve in the cold water line. Mark for future emergency use.
3. If pressure reducers or any other restrictions are put in the cold water line, special

precautions should be taken. Consult your local plumbing inspector.

4. Install the combination temperature and pressure safety relief valve in the tapping

provided. Note that this is required by law for safety considerations.

Outlet to floor drain Install into provided tapping

Manual

Release
Lever


Temperature and Pressure Relief Valve

Temperature
Probe

5. Install a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of

any type should be installed between the relief valve and tank or in the drain line.


FILLING THE HEATER

1. Completely close the drain valve.
2. Open the highest hot water faucet to allow all air to escape from piping.
3. Open the valve to the cold water inlet and allow the heater and piping system to

completely fill, as indicated by a steady flow of water from the open faucet.

ELECTRICAL INSTALLATION

1. Enter the electrical service entrance with properly sized feeder leads, conforming to

the voltage stamped on the rating plate. Note: A separate fused branch circuit,
conforming to local or National Electric Codes, must be provided by a qualified
electrician.

2. Connect these power leads to wires enclosed in junction box with wire nuts. Refer to

wiring diagram.

CAUTION

: There is a risk of electric shock in an ungrounded service. It is critical that

this unit be wired with a power supply that has a service ground wire available. Be
sure to connect the ground wire to the green ground wire provided in the junction box.

3. Mark the electrical shut off clearly for future emergency use.
4. Field connections with aluminum conductors must use connectors approved for

copper to aluminum connection.

5. All other electrical connections are made at the factory; therefore, no other electrical

connections are necessary.