Product Description

MS-9200UDLS PN 52750:E1 01/27/09

15

Communication Confirmation (Kissoff) LED

Touchtone/Rotary dialing

Programmable Make/Break Ratio

EIA-232 Printer/PC interface (variable baud rate)

80-character LCD display (backlit)

Real-time clock/calendar with daylight savings time control

History file with 1,000 event capacity

Advanced fire technology features:
 Automatic drift compensation
 Maintenance alert
 Detector sensitivity test capability (NFPA 72 compliant)
 Automatic device type-code verification
 Point trouble identification

Waterflow selection per module point

Alarm verification selection per detector point

Walktest, silent or audible

PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant)

Silence inhibit timer option per NAC

Autosilence timer option per NAC

Continuous, March Time, Temporal or California code for main circuit board
NACs with two-stage capability

Selectable strobe synchronization per NAC

Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules,
ACS annunciators or ANN-80 Remote annunciator

Auto-program (learn mode) reduces installation time. Reports two devices set to
the same address

Password and key-protected nonvolatile memory

User programmable password

Fully programmable from local keypad or optional keyboard

Optional PK-CD (contains PS-Tools utility) for local or remote Upload/
Download of program and data

Compatible with Fire-Lite’s newer series devices in LiteSpeed and CLIP mode
(refer to SLC Wiring Manual for a list of compatible addressable devices)

Compatible with legacy Fire-Lite 300 Series devices in CLIP mode only (refer to
the SLC Wiring Manual for a list of compatible addressable devices)

Optional 4XTMF module (conventional reverse polarity/city box transmitter)

ANN-BUS for connection to following optional modules (cannot be used if ACS
annunciators are used):
 ANN-80 Remote Annunciator
 ANN-I/O LED Driver
 ANN-S/PG Printer Module
 ANN-RLY Form-C Relay Module
 ANN-LED Annunciator Module annunciates alarm, trouble and supervisory
 ANN-RLED Annunciator Module annunciates alarms only

Automated activation of the ACC-25/50(ZS/T) Audio-Command-Center

Legacy ACS/TERM Annunciators (cannot be used if ANN annunciators are
used):
 ACS Series-LED Zone Annunciators
 LDM Graphic Annunciator Series
 LCD-80F Liquid Crystal Display point annunciator
 ACM-8RF Relay Module