3

598-1303-01

❒

Align the light control cover plate and the junction

box holes. Secure with the mounting screws.

❒

If not installed on a weatherproof box or if an adaptor

plate (not included) was used,

caulk the wall plate

and mounting surface with silicone.

❒

Adjust the lamp holders by loosening the lock nuts
but do not rotate the lamp holders more than 180°
from the factory setting. When screwing in the flood-
lamps, do not overtighten.

Keep lamps at
least 1" (25 mm)
from the sensor.

Avoid water damage and
electrical shock - keep lamp
holders below horizontal.

Lock nuts

M

ount

the

L

ight

C

ontroL

To Deactivate the Flash Alert

❒

Remove the light fixture if necessary.

❒

Locate the (Blue) wire loop coming from the sensor

inside the canopy.

❒

Cut the (Blue) wire loop.

❒

Securely attach wire nuts (supplied) to each of the

cut ends of the (Blue) wire.

DO NOT connect the

wires together.

❒

Mount light control to wall or eave.

WARNING: Turn power off at circuit breaker

or fuse.

Bottom of Sensor

ON-TIME

10 5 1 TEST

MIN MAX

SENS

TEST AND ADJUSTMENT

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

❒

Turn on the circuit breaker and light switch.

❒

Turn the SENSITIVITY (SENS) control to the mid posi-

tion and the ON-TIME control to the TEST position.

Flash Alert - Deactivated

(Blue)