Specifications – Heath Zenith Motion Sensor Light Control 5408 / 5410 User Manual

Page 4

Advertising
background image

4

598-1303-01

Motion

Motion

The detector is most sensitive to motion across its field
of view.

Maximum Range

Maximum

Coverage Angle

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or unwanted traffic may trigger

the control.

•

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

60 ft.

(18.3 m)

8 ft.

(2.4 m)

110°

Least Sensitive

Most Sensitive

Sensor

❒

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

❒

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (2.5 cm) away from
the lamps.

❒

Adjust the SENSITIVITY as

needed. Too much sensitivity
may increase false triggering.

❒

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

❒

Set the amount of TIME you

want the lights to stay on after motion is detected
(1, 5, or 10 minutes).

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 60 ft. (18.3 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . Up to 110°
Electrical Load . . . . . . Up to 300 Watt Maximum In-

candescent [Up to 150 Watt
maximum each lamp holder.]

Power Requirements . 120 VAC, 60 Hz
Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1, 5, 10 minutes
Range . . . . . . . . . . . . Adjustable

HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features
in products previously sold.

WARNING - Risk of fire. Do not aim the lamps

at a combustible surface within 3 ft. (1 m).

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.

Advertising