Three elbows – Heat & Glo Fireplace ST-36TRLP-IPI User Manual

Page 34

Advertising
background image

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI • 2176-900 Rev. G • 3/13

34

INSTALLED

HORIZONTALLY

H

3

H

2

V

1

H

1

3. Rear Vent - Horizontal Termination - (continued)

Two Elbows

Figure 7.15

Figure 7.16

Three Elbows

H

2

V

1

H

1

H

1

Maximum

V

1

Minimum

H

2

Maximum

H

1

+ H

2

Maximum

1 ft.

610 mm

6 in.

152 mm

1 ft.

305 mm

1 ft

305 mm

2 ft.

914 mm

1 ft.

305 mm

2 ft.

610 mm

3 ft.

914 mm

3 ft.

914 mm

2 ft.

610 mm

4 ft

1.2 m

6 ft.

1.8 m

3 ft.

914 mm

3 ft.

914 mm

7 ft.

2.1 m

9 ft.

2.7 m

3 ft.

914 mm

4 ft.

1.2 m

10 ft.

3 m

12 ft.

3.7 m

3 ft.

914 mm

5 ft.

1.5 m

12 ft.

3.7 m

15 ft.

4.6 m

3 ft.

914 mm

6 ft.

1.8 m

15 ft.

4.6 m

18 ft.

5.5 m

V

1

+ H

1

+ H

2

= 50 ft (15.2 m) Maximum H

1

= 3 ft (914 mm) Maximum

*H

1

+ H

2

= 18 ft (5.5 m) Maximum

H

1

Maximum

V

1

Minimum

H

2

+ H

3

H

1

+ H

2

+ H

3

Maximum

6 in.

152 mm

6 in.

152 mm

6 in.

152 mm

1 ft.

305 mm

1 ft.

305 mm

1 ft.

305 mm

2 ft.

610 mm

3 ft.

914 mm

3 ft.

914 mm

2 ft.

610 mm

3 ft.

914 mm

6 ft.

1.8 m

3 ft.

914 mm

3 ft.

914 mm

6 ft.

1.8 m

9 ft.

2.7 m

3 ft.

914 mm

4 ft.

1.2 m

9 ft.

2.7 m

12 ft.

3.7 m

V

1

+ H

1

+ H

2

+ H

3

= 40 ft (12.2 m) Maximum H

1

= 3 ft (94 mm) Maximum

H

1

+ H

2

+ H

3

= 12 ft (3.7 m) Maximum

Advertising
This manual is related to the following products: