Hobart Welding Products CHAMPION 4500 User Manual

Page 32

Advertising
background image

OM-4418 Page 28

Trouble

Remedy

Erratic output at generator power ac

receptacles.

Check fuel level.

Check Amperage control setting. Set Amperage control at Max for generator power.

Check receptacle wiring and connections.

Check governor linkage for smooth, non-binding operation.

Service air cleaner according to engine manual.

Have Factory Authorized Service Agent check engine speed, and adjust if necessary.

C. Engine

Trouble

Remedy

Engine will not start.

Check fuel level (see Section 5-5).

Move choke control to correct position (see Section 6-1).

Open fuel valve (see Section 5-5). Close fuel valve before moving unit or carburetor may flood and make

starting difficult.

Check oil level (see Section 5-5). Low oil level shutdown may stop if oil level is too low. Refill crankcase

with proper viscosity oil for operating temperature.

Have Factory Authorized Service Agent check low oil level shutdown switch.

Engine stopped during normal

operation.

Check fuel level (see Section 5-5).

Open fuel valve (see Section 5-5). Close fuel valve before moving unit or carburetor may flood and make

starting difficult.

Check oil level (see Section 5-5). Low oil level shutdown may stop if oil level is too low. Refill crankcase

with proper viscosity oil for operating temperature.

Unstable or sluggish engine speeds.

Check governor linkage for smooth, non-binding operation.

Tune-up engine according to engine manual.

Have Factory Authorized Service Agent check engine speed, and adjust if necessary.