Mount the SL-6107 into the junction box with the two junction box

screws.

Turn the circuit breaker back on.

Preset the controls: Time to minutes, Photo Adjustment fully

clockwise. Cover the lens with masking tape.

With the motion sensor in the “ON” position, turn the remote

switch on and off several times. Go to step 1, 2, or 3, depending
on results.

inStaLLation

* turn power off before rewiring!

Test again. Go

to 2 or 3.

If light does not

turn on:

1.

Exchange*

Control’s

Red

⇔ Black

wires.

If light turns

on with remote

switch in either

position:

3.

Set sensor to “AUTO”. Wait for the

unit to warm up (up to 1 min.). If the

remote switch can turn the lights on,

it’s OK. Otherwise:

Exchange* Control’s

Black

⇔ Brown wires. Remove

the tape. Go to the next page.

2.

If light turns on in

only one position

of remote switch:

Exchange*

Control’s

Red

⇔ Brown

wires.

troubleshooting Wiring connections

Test again. Go

to 1 or 3.