[d] CONTROLS AND ADJUSTMENTS

The Dip Switch is factory-adjusted to the following positions:

FOR MODELS WITH THERMOSTAT:

Switch Nos. 1 and 2:

Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature

at the Evaporator outlet.

Switch Nos. 3 and 4:

Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker

resumes operation in 2 seconds. Then the Pump Motor drains the Water Tank
for the time determined by the Drain Timer. The Drain Timer also determines the
time to restrain completion of a defrost cycle, i.e. the minimum defrost time.

Switch Nos. 5 and 6:

Used for adjustment of the Drain Counter.
The Pump Motor drains the Water Tank at the frequency determined by the Drain

Counter.

FOR MODELS WITH MECHANICAL BIN CONTROL:

DIP SWITCH NO.

1

2

3

4

5

6

7

8

9

10

KML-250 MAH

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON

OFF

KML-250 MWH

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

ON

350M_F, 350M_H

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

ON

KML-450M_F, M_H

KML-600MAF, MAH

KML-600MWF, MWH

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

KML-600MRF, MRH

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

ON

DIP SWITCH NO.

1

2

3

4

5

6

7

8

9

10

KML-250 MAH

OFF

OFF

OFF

ON

ON

ON

ON

OFF

ON

OFF

KML-250 MWH

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

350M_F, 350M_H

OFF

OFF

OFF

ON

ON

ON

ON

OFF

OFF

ON

KML-450M_F, M_H

KML-600MAF, MAH

KML-600MWF, MWH

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON

KML-600MRF, MRH

ON

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

ON