Hoshizaki KML "F" SERIES User Manual

Page 41

Advertising
background image

41

3) Drain Timer

The Drain Timer is factory-adjusted, and no adjustment is required.

SETTING

TIME

Dip Switch

Dip Switch

No. 3

No. 4

T1

T2

OFF

OFF

10 seconds

150 seconds

ON

OFF

10 seconds

180 seconds

OFF

ON

10 seconds

120 seconds

ON

ON

20 seconds

180 seconds

T1: Time to drain the Water Tank
T2: Time to restrain defrost completion

4) Drain Counter

CAUTION

Do not adjust the Drain Counter, or the Evaporator may freeze up.

The Drain Counter is factory-adjusted to drain the Water Tank every 10 cycles, and no
adjustment is required. However, where water quality is bad and the icemaker needs a
pump drain more often, the Drain Counter can be adjusted as shown in the table below:

2) Defrost Timer

No adjustment is required under normal use, as the Defrost Timer is adjusted to the suit-
able position. However, if necessary when all the ice formed on the Evaporator does not
fall into the bin in the harvest cycle, adjust the Defrost Timer to longer setting by adjusting
the Dip Switch (No. 1 & 2) on the Controller Board.

SETTING

TIME

Dip Switch

Dip Switch

No. 1

No. 2

OFF

OFF

60 seconds

ON

OFF

90 seconds

OFF

ON

120 seconds

ON

ON

180 seconds

Advertising
This manual is related to the following products: