INSTALLATION

For easy installation, select an existing light operated
by a wall switch for replacement.
For best performance, mount the fixture about 8 feet
(2.4 m) above the ground.

NOTE: If fixture is mounted

higher than 8 ft. (2.4 m), aiming the sensor down will reduce
coverage distance.

For eave mount only:

For under eave installation, the sensor head must
be rotated
as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.

❒

Rotate the sensor head towards the clamp screw

joint.

❒

Then rotate the sensor head clockwise 180° so the

controls face down.

Control Switch

Joint Clamp

Move ON-TIME Switch

to 1, 5, or 10 minutes

Mode Switching Summary

Flip light switch

off for one second

then back on*

MANUAL MODE

AUTO

TEST

* If you get confused while switching modes, turn the

power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.

CAUTION to avoid fire or burn hazards:

• Allow fixture to cool before touching. The bulb

and fixture operate at high temperatures.

• Keep fixture at least 2" (5 cm) from combustible

materials. Do not aim at objects closer than 3 feet
(1 m).

• Re-lamp with type T 150W (or less) halogen 120

VAC lamp only.

Wall Mount

Eave Mount