Test and adjustment – Heath Zenith SH-5511 User Manual

Page 4

Advertising
background image

4

598-1159-06

ON - TIME

10 5 1 TEST

MIN

MAX

SENS

Bottom of Sensor

TEST AND ADJUSTMENT

NOTE: Sensor has a 1

1

/

2

minute warm up period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

❒

Turn on the circuit breaker and light switch.

Motion

Motion

Maximum Range

Maximum

Coverage Angle

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating vents and air conditioners. These heat
sources could cause false triggering.

• Areas where

pets or traffic may trigger the control.

•

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

60 ft.

(18.3 m)

8 ft.

(2.4 m)

110°

Least Sensitive

Most Sensitive

Sensor

❒

Loosen the clamp screw in the

sensor ball joint and gently
rotate the sensor.

❒

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down, or
sideways to change the cover-
age area.

Keep the sensor at

least 1" (2.5 cm) away from
the lamps.

❒

Adjust the SENSITIVITY

as needed. Too much
sensitivity may increase false
triggering.

❒

Secure the sensor head by
tightening the clamp screw.

Do not overtighten the screw.

❒

Set the amount of TIME you want the lights to stay

on after motion is detected (1, 5, or 10 minutes).

❒

Turn the SENSITIVITY (SENS) control to the medium

position (halfway between MIN and MAX) and the
ON-TIME control to the TEST position.

Clamp
Screw

Ball
Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

NOTE: If fixture is mounted higher than 8 ft. (2.4 m), aiming
the sensor down will reduce coverage distance.
The detector is less sensitive to motion directly towards it.

WARNING: Risk of fire. Do not aim the bulbs

at a combustible surface within 3 ft. (1 m).