6

7

Wire Labeling

CAUTION! TURN OFF POWER TO THE HEAT PUMP SYSTEM BEFORE YOU ATTEMPT

TO ACCESS THE THERMOSTAT’S WIRING.

IMPORTANT! BEFORE DISCONNECTING ANY WIRES FROM THE EXISTING

THERMOSTAT, APPLY THE PROVIDED SELF-ADHESIVE LABELS TO THE WIRES.

• Use the information in Table 1 below and the provided adhesive labels to label the wires.

IGNORE THE COLOR OF THE WIRES since these do not always comply with the

standard.

• After labeling the wires, disconnect them from the existing thermostat terminals.

• Remove existing wallplate. To make sure wires do not fall back into wall opening, you may

want to secure them to the wall.

• If the hole in wall is larger than necessary for wires, seal the hole with insulating material so

that no hot or cold air can enter the back of the thermostat from the wall. This air could cause

a false thermostat reading.

• A wiring diagram is provided on page 23 of these instructions.

Table 1

If the terminal letter

on the existing

thermostat is. . .

R, V-VR, or VR-R

R

Y, Y1, or M

Y1

Y2

Y2

W1, W2, or W-U

W2

E

E

G or F

G

O or R

O

B

B

L or X

L

C, X, or B

C (Required)

. . .then mark the

wire with adhesive

label