15

system

off

cool

heat

fan

auto
refresh

on

reset

filter

em

heat

sys em aux

A

B

C

D

E

F

G

H

Switches and Buttons

Switches and Buttons

A LCD Readout - displays indoor temperature, set temperature, and information about the heat pump

system’s operation and status.

B System Switch - “em heat” is the Emergency Heat. NOTE: The Emergency Heat Mode is not an energy

saving mode, so use it only when necessary. “heat” is the normal heat mode. “off” turns the system off.

“cool” is the normal cooling mode.

C Fan Switch - In Auto mode, the fan runs when the system is on for heating or cooling. The Refresh mode

sets the fan to run automatically at intervals of 10, 15, 20, or 30 minutes out of every hour when the system

is not running for heating or cooling. In the On mode, the fan runs continuously regardless of system

status.

D Reset button - push the Reset button with the end of a paper clip to reset the thermostat and return to its

previous settings.

E Filter button - resets the filter time counter.

F Down button - used to change the temperature setting and the option settings.

G Up button - used to change the temperature setting and the option settings.

H System LED’s - for heat pump systems that have fault detection capabilities, the “sys” LED glows red

when the thermostat has detected a fault through the L terminal connection from the heat pump. The “em”

LED glows red when Emergency Heat is turned on. The “aux” LED glows green when the auxiliary heat is

turned on.