Test and adjustment, Specifications – Heath Zenith Motion Sensor Entryway Light SL-5610/15 User Manual

Page 3

Advertising
background image

3

598-1101-03

TEST AND ADJUSTMENT

❒

Turn on the circuit breaker and light switch.

Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heat-

ing vents or air conditioners. These heat sources
could cause false triggering.

• Areas where

pets or traffic may trigger the control.

•

Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.

110°

30 ft (9.1m)

The detector is less sensitive to motion directly towards
it and more sensitive to across motion.

7ft
(2.1 m)

Maximum Range

Maximum

Coverage Angle

❒

Rotate the sensor base left

and right to aim the sensor.
Adjust the sensor eye up
and down to obtain desired
coverage range.

❒

Walk through the coverage

area noting where you are
when the lights turn on. Move
the sensor head up, down,
or sideways to change the
coverage area.

❒

Set SENSITIVITY as needed.

Too much sensitivity may
increase false triggering.

❒

Set the amount of TIME the

lights stay on after motion is de-
tected (1, 5, or 10 minutes).

In the test position shown above, the light will turn
on for 5 seconds each time motion is detected
dur-
ing both daylight and darkness.

SPECIFICATIONS

Range . . . . . . . . . . . . . . Up to 30 ft (9.1 m) [varies with

surrounding temperature].

Sensing Angle . . . . . . . . Up to 110°
Electrical Load . . . . . . . . Up to 60 Watt Maximum In-

candescent

Power Requirements . . . 120 VAC, 60 Hz
Operating Modes . . . . . . TEST, AUTO and MANUAL

OVERRIDE

Time Delay . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.

ON-TIME

SENS

TEST 1 5 10

MIN MAX

Bottom of Sensor

Least Sensitive

Most Sensitive

Sensor

Motion

Motion

NOTE: Sensor has a 1

1

/

2

minute calibration period

before it will detect motion. When first turned
on, wait 1

1

/

2

minutes.

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

❒

For aiming, turn the SENSITIVITY (SENS) control

to the mid position and the ON-TIME control to the
TEST position.

Advertising