Notice, Cleaning, Air supply maintenance – Harbor Freight Tools CENTRAL PNEUMATIC 94572 User Manual

Page 14: Storage

Advertising
background image

Page 14

For technical questions, please call 1-800-444-3353.

Item 94572

NOTICE

Clean the Spray Gun IMMEDIATELY after use.

Delayed or inadequate cleaning will permanently clog the Spray Gun.

SAFETY

Op
ERA
TION

M

AINTENANCE

SETU
p

Cleaning

Solvent Selection
Follow the paint manufacturer’s

recommendations for cleaning, solvent type,

and disposing of used solvent.

• Latex paints: Do not use

this Spray Gun with latex paint.

IMpORTANT: Do not use mineral spirits

on latex paints or the mixture will congeal,

making it very difficult to remove.

• Oil Based paints: Use mineral spirits.

WARNING! TO pREVENT FIRE,

IF A FLAMMABLE SOLVENT

NEEDS TO BE USED,

ADHERE TO THE FOLLOWING:

a.

Follow solvent manufacturer’s clean up

instructions and safety precautions.

b.

Flush Spray Gun a full hose

length from air compressor.

c.

If collecting flushed solvents in

metal container, transfer to nonmetal

container, and flush metal container.

d.

Work far away from any ignition

sources in a vapor free area.

e.

Keep class ABC fire extinguisher nearby.

After each use:
1. Empty the Cup and clean it with the solvent.
2. Fill the Cup with solvent and spray it through

the Spray Gun into a container, while shaking

the Spray Gun. Once the Cup is empty, repeat

the process until the solvent comes out clean.

3. Disconnect from the air source.
4. After disconnecting, point the Spray Gun into

the spent solvent container and squeeze the

Trigger again to make sure no air remains.

5. Remove Nozzle and soak it in solvent

until it is clean. Use old toothbrush

and toothpicks to remove any paint.

CAUTION: Do not immerse Spray Gun.
Note: Do not use metal objects to clean the

Nozzle to prevent damage to the passages.
6. Inspect fluid needle and make sure

it is not bent. If it is bent, have it

replaced by a qualified technician.

7. Use appropriate solvent

(see

Solvent Selection, left)

to wipe down Spray Gun body.

8. Lubricate Spray Gun after cleaning.

A non-silicon oil or a light lubricant may be

used on threaded connections before storing.

Solution Disposal
After cleaning, dispose of cleaning solution

according to the solution manufacturer’s

directions and local hazardous waste standards.

Air Supply Maintenance

Every day, perform maintenance on the air supply according

to the component manufacturers’ instructions.

Storage

Store in a dry, secure area out of reach of children.

Advertising