Notice, Troubleshooting - spray pattern diagnosis, Problem possible causes likely solutions – Harbor Freight Tools CENTRAL PNEUMATIC 94572 User Manual

Page 15

Advertising
background image

Page 15

For technical questions, please call 1-800-444-3353.

Item 94572

NOTICE

Clean the Spray Gun IMMEDIATELY after use.

Delayed or inadequate cleaning will permanently clog the Spray Gun.

SAFETY

Op

ERA

TION

M

AINTENANCE

SETU

p

Troubleshooting - Spray pattern Diagnosis

Note: The drawings on the left below resemble symptoms of spray pattern problems.

Refer to the accompanying possible causes and likely solutions to the right.

problem

possible Causes

Likely Solutions

Heavy

center

pattern

1. Pattern Knob partially closed.
2. The paint is too thick.

3. The air pressure is too low.

1. Open Pattern Knob more.
2. Thin paint according to the

manufacturer’s instructions.

3. Increase air pressure within

the Operating Air Pressure.

Light

center

pattern

1. High air pressure.
2. Fluid Knob not open enough.
3. Pattern Knob open too far.

1. Reduce air pressure.
2. Open Fluid Knob.
3. Partially close Pattern Knob.

Heavy top/

bottom

pattern

1. Nozzle plugged.
2. Nozzle loose or dirty seal.
3. Dried paint on fluid tip.

4. Damaged Needle.

1. Clean Nozzle.
2. Clean and tighten Nozzle and seal.
3. Use a nonmetallic point

to clean Nozzle.

4. Have qualified technician

replace Needle.

Pattern

on right or

left only

1. Dirt on one side of fluid tip.
2. Holes on one side of

Nozzle are plugged.

3. Damaged Needle.

1. Clean fluid tip.
2. Clean Nozzle with nonmetallic point.

3. Have qualified technician

replace Needle.

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect air supply before service.