A-31 – Hitachi J300U Series User Manual
Page 143

A-31
Display with HOP, HRW Display with DOP, DRW
Function No. with digital operator
Data read/copy
Function mode
Layer
Data display
No.
Data display
Alterability
No.
Data
HRW DRW
Transmission speed selection
4-7
1 BAUD
1:600 bps F-46
COM BAUD 0600 bps
N
—
—
Y
N
Station number selection
2 NUMBER 1
COM NUMBER 01
N
—
—
Y
N
Bit length selection
3 LENGTH 0: 8
COM LENGTH 8
N
—
—
Y
Y
Parity ON/OFF selection
4 PAR-1
1: ON
COM PAR-SEL1 ON
N
—
—
Y
Y
Odd/even parity selection
5 PAR-2
0: EVN
COM PAR-SEL2 EVN
N
—
—
Y
Y
Stop bit length selection
6 STOPBIT 0: 2
COM STOPBIT 2
N
—
—
Y
Y
Relay output terminal RYA signal
4-8
1 RYA
3: RUN
F-48
RELAY RYA RUN
N
—
—
Y
N
selection
Relay output terminal RYB signal
2 RYB
0: CST
RELAY RYB CST
N
—
—
Y
N
selection
Relay output terminal RYC signal
3 RYC
4: OTQQ
RELAY RYC OTQ
N
—
—
Y
N
selection
Extension function setting
Setting only for digital operator
Y
F14
A 0
N
N
Voltage command adjustment
Setting only for digital operator
Y
A80
N
N
Current command adjustment
Setting only for digital operator
Y
A81
N
N
set