25

Connection to the control signal terminal (continued)

Control data table

Caution

If computer sends the undefined command code or data code, Projector can not guarantee operation.

Command is consisted of 2 command bytes and following data bytes.
1-st byte indicates the kinds of commands and the length of command.

'0xH' : Error-reply

Projector sends to computer.

'1xH' : Command reply

Projector sends to computer.

'2xH' : Ask command

Computer sends to Projector.

'3xH' : Set command

Computer sends to Projector.

'4xH' : Default set command

Computer sends to Projector

'5xH' - 'FxH' : Reserved
'x' indicates the length of data bytes.

2-nd byte indicates the command code 'yy' as command table.
Data table shows the data byte.

Item

Data code

MOUSE

00h=stop mouse emulation. 01~7Fh=start mouse emulation

COMMUNICATE

0Xh=8N1
1Xh=7N1
X0h=1200bps, X1h=2400bps, X2h=4800bps, X3h=9600bps, X4h=19200bps

POWER

1Eh=Power off (Standby mode), 1Fh=Power on

MIRROR

00h=Normal, 01h=H:Invert, 02h=V:Invert, 03h=H&V:Invert

INPUT

11h=VIDEO1, 12h=VIDEO2, 21h=RGB1, 22h=RGB2

VIDEO
SYSTEM

00h 00h=Auto, 00h 01h=NTSC, 00h 04h=NTSC4.43
00h 02h=PAL, 00h 03h=SECAM, 00h 05h=M-PAL

VOLUME

00h (min) ~ 24h (max)

MUTE

00h=Mute off, 01h=Mute on

BRIGHT

00h 00h 00h (dark) ~ 00h 00h 24h (brite)

CONTRAST

00h 00h 00h (lower) ~ 00h 00h 24h (higher)

COLOR

00h 00h 00h (less) ~ 00h 00h 24h (more)

TINT

00h 00h 00h (red) ~ 00h 00h 24h (green)

SHARPNESS

00h 00h 00h (soft) ~ 00h 00h 24h (sharp)

H. PHASE

00h 00h 00h ~ 00h 00h 1Fh

H. POSIT

00h 00h 00h 00h (left) ~ 00h 00h 37h 04h (right)

H. SIZE

00h 00h 78h 05h (narrow) ~ 00h 00h 30h 0Eh (wide)

V. POSIT

00h 00h 01h 00h (down) ~ 00h 00h 58h 04h (up)

BLANK

0Xh=Blank off
1Xh=Blank on

bit0 0=Blue off, 1=Blue on, bit1 0=Green off, 1=Green on
bit2 0=Red off, 1=Red on, bit3 0=Not change, 1=change

REVEAL

X1h=Reveal down, X4h=Reveal right, X=0 (slow) ~ 7 (fast)

MAGNIFY

(1) Circuit codes when ask code and default set code are issued (Number of data byte=1)

00h=normal display, 01h=magnified display

(2) When magnification is set by setting codes (Number of data bytes=6)

1st, 2nd data bytes: magnification starting positions in horizontal direction (left end)

00h 00h (left) ~ 3Ch 05h (right)

3rd, 4th data bytes: magnification starting positions in vertical direction (top)

00h 00h (top) ~ 0Dh 04h (bottom)

5th, 6th data bytes: Horizontally magnified dot number data

64h 00h (large) ~ 20h 06h (small)

FREEZE

00h=normal display, 01h=still picture display

Advertising