Quickspecs, Hp storageworks 2000fc modular smart array – HP 2000fc User Manual

Page 5

Advertising
background image

operations. It can withstand two simultaneous drive failures without downtime
or data loss. RAID 10 is mirroring and striping without parity. It is the most
popular of the multiple RAID levels, allowing large arrays with high
performance in most cases and superior fault tolerance. RAID 50 combines
the block striping and parity of RAID 5 with the straight block striping of RAID
0, yielding higher performance than RAID 5 through the addition of RAID 0,
particularly during writes.

Performance

Performance

Performance

Performance

Performance numbers are a guideline as established by tests in a lab
environment. Forty-eight 300GB 15K SAS drives were used in
dual controller configurations of four vDisks with 12 physical drives per
vDisk. Each vDisk presented a
single volume of maximum capacity according to RAID level.
Number and type of applications, number of hosts will affect overall
performance.

Workload

Workload

Workload

Workload

MSA2012fc

MSA2012fc

MSA2012fc

MSA2012fc

MSA2212fc

MSA2212fc

MSA2212fc

MSA2212fc

MSA2000 RAID 10 Performance Results (rounded)
Random Reads IOPs

10,600

11,200

Random Writes IOPs

5,000

7,800

Random Mix IOPs 60/40 read/write

6,700

8,900

Sequential Reads MB

650

1,000

Sequential Writes MBs

330

470

MSA2000 RAID 5 Performance Results (rounded)

Random Reads IOPs

10,200

10,700

Random Writes IOPs

1,700

2,400

Sequential Reads MBs

670

1,000

Sequential Writes MBs

380

580

Random Mix IOPs 60/40 read/write

3,500

5,700

Configuration and

Configuration and

Configuration and

Configuration and
Management Tools

Management Tools

Management Tools

Management Tools

HP StorageWorks MSA Storage Management Utility (SMU). Management
access, out-of-band: WEB GUI, CLI. Interface Types: Mini DB9 RS232,
10/100 Ethernet Protocols Supported SNMP, SSL, SSH, SMTP, HTTP, Telnet

Hot Plug Expansion and

Hot Plug Expansion and

Hot Plug Expansion and

Hot Plug Expansion and
Replacement Support

Replacement Support

Replacement Support

Replacement Support

The MSA2000fc supports hot plug expansion and replacement of redundant
controllers, enclosures, fans, power supplies, and I/O modules for simple,
fast installation and maintenance.

Snapshot and Clone

Snapshot and Clone

Snapshot and Clone

Snapshot and Clone

Optional controller based functionality. Offers higher levels of data
protection, enabling an almost instant recovery from data failure or
corruption. Offers alternative development testing of 'offline' production data
and the ability to backup snapped/cloned data.

QuickSpecs

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

Family Information

DA - 12991 EMEA — Version 5 — September 15, 2008

Page 5

Advertising
This manual is related to the following products: