MSA2000 Snapshot and

MSA2000 Snapshot and

MSA2000 Snapshot and

MSA2000 Snapshot and
Volume Copy Software

Volume Copy Software

Volume Copy Software

Volume Copy Software

Product Features

Product Features

Product Features

Product Features

Data Protection

Data Protection

Data Protection

Data Protection

Snapshots create up to 64 point-in-time pictures of data
Volume Copies create up to 128 point-in-time copies of data
Recovery is instant - revert data from any previous Snapshot or Volume Copy
Backup 'snapped' data to disk, virtual tape, or physical tape without a backup window

Data Testing

Data Testing

Data Testing

Data Testing

Snap or clone data to test the performance of a software application on 'offline' production data
Snap or clone data to test how a software patch or enhancement will function on 'offline;
production data

HP StorageWorks 2000 Modular Smart Array Snapshot 64 Software LTU

T5512A

HP StorageWorks 2000 Modular Smart Array Snapshot 8 Software LTU

T5513A

HP StorageWorks 2000 Modular Smart Array Snapshot 8 to 64 Upgrade Software
LTU

T5515A

HP StorageWorks 2000 Modular Smart Array Volume Copy Software LTU

T5514A

Path failover (MPIO)

Path failover (MPIO)

Path failover (MPIO)

Path failover (MPIO)

MPIO Basic Failover for Windows provides a single multi-path solution for HP StorageWorks
MSA2000fc Modular Smart Array on HP ProLiant servers by providing basic path failover. Supports
Windows 2003, Windows 2003 R2, and Windows 2003 X64 operating systems.

HP MPIO Full Featured DSM for MSA2000fc v2.2.0.22
Microsoft Windows 2008: Microsoft MPIO is bundled with Windows Server 2008 and must be
installed as an operating system feature.
Failover support for Linux is with Device Mapper 4.0.
Xen: Inbox Device Mapper

HP StorageWorks Storage

HP StorageWorks Storage

HP StorageWorks Storage

HP StorageWorks Storage
Mirroring

Mirroring

Mirroring

Mirroring

HP StorageWorks Storage Mirroring Software provides host-based, continuous replication for customers
seeking a low-cost alternative to fabric or array-based replication. Patented replication and failover
technology continuously captures byte-level data changes as they happen and replicates those changes
to one or more target servers at any location without geographic limitations. By replicating only the bytes
that change, Storage Mirroring Software uses the absolute minimum bandwidth on your existing LAN or
WAN to replicate your data. Storage Mirroring also provides server failover where a production server
can automatically be ‘replaced’ by the storage mirroring server in the event of failure. Couple Storage
Mirroring with MSA2000 Snapshots and/or Volume Copy to achieve an Enterprise class data protection
strategy creating different data recovery points using continuous data protection with Storage Mirroring
and point-in-time data protection with Snapshots and/or Volume Copy.
Storage Mirroring Software supports:

Any DAS, NAS, and SAN storage device.
Any Windows ProLiant server including all ML, DL, and BL platforms
Many Windows platforms including Windows Server 2000, Windows Server 2003, Windows
Server 2003 R2, Windows Storage Server 2003, Windows Storage Server 2003 R2, 64bit
Windows, and Windows on Itanium

For more information visit

http://h18006.www1.hp.com/products/storage/software/sm/index.html

HP StorageWorks Storage Mirroring Software Windows Server Edition 1 LTU

T4441A

QuickSpecs

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

HP StorageWorks 2000fc Modular Smart Array

Optional Software

DA - 12991 EMEA — Version 5 — September 15, 2008