Maintenance – Harman Stove Company SF160 User Manual

Page 13

Advertising
background image

1

Maintenance

maintenance

The spiral chamber is basically self-cleaning. However, if there is a draft problem and you have

been burning wood for a long time with little demand, the spiral chamber will need to be cleaned. To

clean the spiral chamber, remove the stovepipe and scrape any creosote or debris from the top and

front of the chamber. The rear of the chamber should not have much accumulation. If it does, clean it

out.

NOTE: 1/4” to 1/2” of creosote in the spiral chamber is normal.

The pipes inside the firebox will accumulate creosote if the demand for heat is too low, when

burning wood. 1/8” to 1/4” of creosote is normal on the pipes and firebox walls. If more creosote has

accumulated, it should be scraped off of these surfaces.

NOTE: Creosote in the firebox can be burned off by burning coal for a few days.

The fire bricks may become cracked during the course of normal operation. A cracked brick

that is still in place, is still doing its job, and need not be replaced immediately. If a brick is broken, and

has fallen out of place, it should be replaced before any further burning occurs. The firebricks used in

the Trident Boiler are available for replacement from your Harman dealer.

Gaskets on the doors are there to regulate air to the firebox. If a gasket is failing, you’ll notice

difficulty in controlling the fire. Inspect the gaskets regularly, and replace with Harman supplied mate-

rial only.

Specifications

Sf-160

Sf-260

Sf-360

Heating Capacity (Square Feet)

2200 Max.

3200 Max.

4500 Max.

Approximate BTU per hour (wood or coal)

90,000

130,000

180,000

AMP Rating

40

40

40

Water Capacity (US Gallon)

25

32

42

Weight

640 Lbs

780 Lbs

925 Lbs

Hydro-Pressure Tested

Yes

Yes

Yes

Firebox Dimensions (inches)

16W x 22L x 19H

18W x 26L x 20H

18W x 30L x 25H

Recommended Log Length (inches)

19

23

27

Door Opening Size (inches)

11 x 13

13 x 13

13 x 13

Overall Dimensions (inches)

23W x 23.5L x 45H

26W x 27.5L x 45.5H

26W x 31.5L x 51.5H

Flue Size (diameter)

6 inch

7 inch

7 inch

Flue Height (top of flue)

37.5 inches

38.75 inches

44 inches

Number Of Grates (10 Lbs. Each)

4

5

6

Type Of Fuel

Coal / Wood

Coal / Wood

Coal / Wood

Water Inlet and Outlet Size

1.25 NPT

1.25 NPT

1.25 NPT

Automatic Draft Control

Yes

Yes

Yes

Aquastat

Yes

Yes

Yes

Temperature / Pressure Gauge

Yes

Yes

Yes

ASME Pressure Relief Valve

Yes

Yes

Yes

Ash Pan With Handle

Yes

Yes

Yes

Domestic Hot Water Coil (optional)

4 GPM

4 GPM

4 GPM

Approximate BTU per hour (electric option)

30,000

30,000

30,000

Kilowatt Rating (electric option)

9

9

9

Advertising