PJLink command (continued)

Commands

Control Description

Parameter or Response

ERST ?

Error Status inquiry

1st byte: Refers to Fan error; one of 0 to 2

2nd byte: Refers to Lamp error; one of 0 to 2

3rd byte: Refers to Temptrature error; one of 0 to 2

4th byte: Refers to Cover error; one of 0 to 2

5th byte: Refers to Filter error; one of 0 to 2

6th byte: Refers to Other error; one of 0 to 2
The mearning of 0 to 2 is as given below
0 = Error is not detected;

1 = Warning; 2 = Error

LAMP ?

Lamp Status inquiry

1st number (digits 1 to 5): Lamp Time
2nd number : 0 = Lamp off, 1 = Lamp on

INST ?

Input Source List inquiry 11 12 21 22 23 31 33 41 51 52

NAME ?

Projector Name inquiry

Responds with the name set in the item

PROJECTOR NAME of the NETWORK menu

INF1 ?

Manufucturer's Name

inquiry

HITACHI

INF2 ?

Model Name inquiry

CP-X8150

CP-X8160

CP-WX8240

CP-WX8255

CP-SX8350

CP-WU8440

CP-WU8450

INFO ?

Other Information inquiry Responds with the factory information and so

on

CLSS ?