B. install fireplace & chimney, C. install chase top – Hearth and Home Technologies A42C User Manual

Page 32

Advertising
background image

32

Slope Downward
(1/4 in. per foot
minimum)

Turn-down

Drip Edge

Chase

2 in. (51 mm) Collar
on Chase Top

.018 (26 ga) min.
Galvanized
Chase Top

Figure 9.3 Chase Top Construction

B. Install Fireplace & Chimney

Install as per Sections 7 and 8.

Heatilator • A36C & A42C • 28396 • Rev AG • 11/08

C. Install Chase Top

• You MUST use a chase top in a chase installation. Chase

tops are available from your Heatilator dealer or may be
fi eld constructed.

• Include a turndown and drip edge to prevent water from

seeping into the chase.

• Include a 2 in. (51 mm) soldered, welded or spun collar

around pipe opening to keep water out.

• Provide a 1/8 in. (3 mm) gap around the fl ue pipe.
• Slope the chase top downward away from the

opening.

WARNING! DO NOT caulk the pipe to the chase top
collar. Restricting air fl ow around chimney may cause
fi re.

• Caulk all seams to prevent leaks.
• Refer to Figure 9.3.

Advertising