Shrouds, A. radiation shield, B. field constructed shrouds – Hearth and Home Technologies A42C User Manual

Page 35

Advertising
background image

35

3 in. (76 mm) tall legs

Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap

Length x Width to fit inside shroud

Figure 10.1 Radiation Shield

10

10

Shrouds

• Chase top shrouds may be fi eld constructed where

permitted by regional building codes.

WARNING! Risk of Fire! Shrouds must be constructed
as specifi ed. Improper construction may overheat chase
top.

NOTICE:

Some regional codes require an agency-Listed

shroud. Consult your local building offi cials.

• Hearth & Home Technologies Inc. supplies UL listed

shrouds. See your dealer for details.

• Shrouds must be constructed of minimum 26 ga sheet

metal.

A. Radiation Shield

• Some shrouds require a radiation shield. Use where

specifi ed.

3 in (76 mm)
minimum

Min.

Base Dim.

Min.

Base Dim.

Min.

Top Dim.

Min.

Top Dim.

Min. Opening

Width

Min. Opening

Width

Figure 10.2 Open Top Shroud Dimensions

B. Field Constructed Shrouds

Heatilator • A36C & A42C • 28396 • Rev AG • 11/08

TS345

TR342

TR342/344TV

Min. Base Dims.

in

23 x 23

28 x 28

26 x 26

mm

584 x 584

711 x 711

660 x 660

Radiation Shield

Required

Min. Top Dims.

in

20 x 20

25 x 25

23 x 23

mm

508 x 508

635 x 635

584 x 584

Min. Opening Width

in

17 x 17

22 x 22

20 x 20

mm

432 x 432

559 x 559

508 x 508

Open Top Shroud (TR342 & TR11/TR11T caps require radiation shield)

• Different shroud designs have been tested for Hearth Technologies fi replace systems using the TR11 and TR11T termination

caps.

• The shrouds must be constructed from a minimum .018 in. (26 ga) thick aluminized steel.
• The wire mesh is optional but recommended and must be .018 in. thick minimum.

Advertising
This manual is related to the following products: