Installation Procedures

Under ceiling

6.35mm

12.7mm

Outdoor unit

Indoor unit

2 cm
or more

Ceiling

Indoor unit

30 cm
or more

Left

Right

1.5m

Floor console

30 cm
or more

30 cm
or more

1.5m

1.5m

Left

Right

may be difference

SELECTING THE MOUNTING POSITION

(1)Do not install where there is the danger of com-
bustible gas leakage.

(2) Do not install near heat sources.

(3) If children under 10 years old may approach

the unit, take preventive measures so that they

cannot reach the unit.

Install at a place that can withstand the weight of the

indoor and outdoor units and install positively so that

the units will not topple or fall.

WARNING

CAUTION

Decide the mounting position with the customer as follows:

1. INDOOR UNIT

(1) Install the indoor unit level on a strong wall, floor,
ceiling which is not subject to vibration.
(2) The inlet and outlet ports should not be obstructed:
the air should be able to blow all over the room.
(3) Install the unit near an electric outlet or special
branch circuit.
(4) Do not install the unit where it will be exposed to
direct sunlight.
(5) Install the unit where connection to the outdoor
unit is easy.
(6) Install the unit where the drain pipe can be easily
installed.
(7) Take servicing, etc. into consideration and leave the
spaces shown in Fig.A. Also install the unit where
the filter can be removed.

Fig.A

8