Performance data sheet, Microbiological performance – HoMedics Restore RWS-1FL User Manual

Page 7

Advertising
background image

13

Microbiological Performance

Bacteria: 99.9999% or 6 log reduction

Virus: 99.99% or 4 log reduction

Cyst: 99.95% or 3.5 log reduction

Intended for the supplemental purification of visually clear tap water only.

Substance

Infl uent Challenge

Concentration

Maximum

Permissable

Concentration

Average

Actual

Reduction

NSF 42 - Aesthetic Effects

Chlorine
- Taste and Odor

2 mg/L ± 10%

1 mg/L

98.9%

Zinc

10 mg/L ± 10%

5 mg/L

86.2%

NSF 53 - Health Effects

Benzene

0.015 mg/L ± 10%

0.005 mg/L

94.4%

Cadmium - pH 6.5

0.03 mg/L ± 10%

0.005 mg/L

91.8%

Cadmium - pH 8.5

0.03 mg/L ± 10%

0.005 mg/L

89.9%

Copper - pH 6.5

3 mg/L ± 10%

1.3 mg/L

89.7%

Copper - pH 8.5

3 mg/L ± 10%

1.3 mg/L

77.9%

Lindane*

0.002 mg/L ± 10%

0.0002 mg/L

99%

Mercury - pH 6.5

0.006 mg/L ± 10%

0.002 mg/L

96.2%

Mercury - pH 8.5

0.006 mg/L ± 10%

0.002 mg/L

94.3%

Tetrachloroethylene

0.015 mg/L ± 10%

0.005 mg/L

93.2%

Toluene

3 mg/L ± 10%

1 mg/L

99.4%

*Compliant for Lindane reduction requirements under NSF/ANSI

Standard 53 as tested by PACE Analytical Services, Inc.

Substance

Infl uent Challenge

Concentration

Maximum

Permissable

Concentration

Average

Actual

Reduction

NSF 53 (1988)

Lead pH 7.5**

0.150 mg/L ± 10%

0.020 mg/L

98.7%

**Meets the lead reduction requirements under NSF/ANSI Standard 53

(1988) as tested by PACE Analytical Services, Inc.

This system has been independently tested by PACE Analytical Services, Inc.

according to NSF/ANSI 53 (1988) for the reduction of lead.

Performance Data Sheet

HoMedics Restore™ Water System-Model: RWS-100
Replacement Filter-Model: RWS-1FL

Distributed by HoMedics, Inc.
3000 Pontiac Trail, Commerce Township, MI 48390

This system has been tested according to NSF/ANSI 42 and 53 for

the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a

concentration less than or equal to the permissible limit for water leaving

the system, as specified in NSF/ANSI 42 and 53. Testing was performed

under standard laboratory conditions, actual performance may vary.

12