D. Condenser

Check the condenser once a year, and clean if required by following the steps below.
More frequent cleaning may be required depending on location.

WARNING

• Move the power switch to the "OFF" position and unplug the unit from the

electrical outlet before cleaning the condenser.

• To reduce the risk of electric shock, do not touch the power switch or plug with

damp hands.

• Condenser fins are sharp. Use care when cleaning.

1) Move the power switch to the "OFF" position and unplug the unit from the electrical

outlet.

2) Remove the 2 screws securing the front panel, then remove the panel. See Fig. 34.
3) Remove the 2 screws securing the louver, then remove the louver.
4) Use a brush attachment on a vacuum cleaner to gently clean the condenser fins. Do not

use too much force, otherwise the fins could be damaged.

5) Replace the louver and front panel in their correct positions. Ensure that the screws are

securely in place.

6) Plug the unit back in. Move the power switch to the "ON" position to start the automatic

icemaking process.

Front Panel

Louver

Fig. 34

Screws

Screws

Condenser

E. Optional Drain Pump HS-5061

If the optional drain pump (HS-5061) is installed, test its operation at least twice a year
as outlined below. Note that the pump has power even when the power switch is in the
"OFF" position.

NOTICE

If the optional drain pump is not operating properly, it will adversely affect
performance, component life, and warranty coverage and may result in costly water
damage.

1) Move the power switch to the "OFF" position, then unplug the unit from the electrical

outlet.

WARNING! To reduce the risk of electric shock, do not touch the power

switch or plug with damp hands.