F. Water Supply and Drain Connections

WARNING

Water supply and drain connections must be installed in accordance with applicable
national, state, and local regulations.

NOTICE

• Normal operating water temperature must be within 45°F to 90°F (7°C to

32°C). Operation of the icemaker, for extended periods, outside of this normal
temperature range may affect icemaker performance.

• To prevent damage to equipment, do not operate the icemaker when the water

supply is off, or if the pressure is below 7 PSIG. Do not run the icemaker until the
proper water pressure is reached.

• Connect to potable water supply only. Do not connect to a hot-water supply.
• In areas where water damage is a concern, install in a contained area with a floor

drain.

• Water line installation to the icemaker is not warranted by Hoshizaki.
• Water-hammer issues must be resolved by a qualified plumber before installing

the icemaker. Water hammer can cause icemaker damage that may lead to water
leakage or flooding.

• If using the optional drain pump (HS-5061), test its operation every time the

icemaker is cleaned and sanitized. See "IV.E. Optional Drain Pump HS-5061" for
details. If the optional drain pump is not operating properly, water could back up
and overflow, leading to costly water damage.

• A plumbing permit and services of a licensed plumber may be required in some areas.
• External filters, strainers, or softeners may be required depending on water quality.

Contact your local Hoshizaki Certified Service Representative for recommendations.

• Water supply inlet is 1/2" female pipe thread (FPT).

Fig. 30

Piping to approved drain.

Leave a 2-inch (5-cm) vertical

air gap between the end of the

pipe and the drain.

2-inch (5-cm)

air gap

Floor

Drain

Water Supply Line

Shut-Off Valve

Water Supply Line

Drain Valve

Water Supply Inlet

1/2" FPT

Drain Outlet

1/2" FPT

Vented Tee Connection

Extend the vent at least 12"

(30 cm) above the drain outlet.

Minimum 1/4" Nominal ID Copper Water Tubing or Equivalent

Minimum 1/2" Nominal ID Hard Pipe

or Equivalent

Be sure there is sufficient extra

water supply line and drain line for

the unit to be pulled out for service.