Using the legend 1000 series – Humminbird Legend 1000 User Manual

Page 4

Advertising
background image

2

USING THE LEGEND 1000 SERIES

Performance

The L

EGEND

1000 S

ERIES

represents a new way of thinking about fishing

electronics. It combines state-of-the-art electronics with the detail of a
traditional sonar paper chart recorder to create the fishfinder of the future.
Minimal, easy-to-understand knob controls provide access to the most
important features. The L

EGEND

1000 S

ERIES

eliminates confusion created by

too many buttons and menus. High technology, high performance, with “back
to basics” operation makes the L

EGEND

1000 S

ERIES

the ideal choice of the

serious angler.

The L

EGEND

1000 S

ERIES

uses sonar to locate and define underwater objects.

Sonar technology is based on sound waves sent into the water in a controlled
“beam” from the transducer. Objects within this beam reflect the sonar signal
back. The L

EGEND

1000 S

ERIES

very accurately measures the distance to these

objects based on the time it takes for the sonar to return. Each object (bottom,
fish or structure) reflects the sonar uniquely, providing information about its
makeup. The L

EGEND

1000 S

ERIES

draws this returned information on the

display.

The L

EGEND

1000 S

ERIES

operates in a wide variety of water conditions, from 2'

to 600' (2000' for the Legend 1000 Deep and 1005 Deep Models). Actual depth
capability depends on many factors such as bottom hardness, water conditions,
and transducer installation. All sonar units typically read to deeper depths in
fresh water than in salt water.

Deep Models Additional Performance

If you purchased a Legend 1000 Deep or a Legend 1005 Deep Model, your
Legend product is equipped with a 50kHz/200kHz dual beam transducer
capable of performing to a depth of 2000 feet. In addition, your unit contains
several extra features that will enhance its sonar performance in deep water.
S

ONAR

V

IEW

allows you to display the sonar information from either beam or

both beams simultaneously. F

ILTER

control allows the filtering algorithms to be

turned off to show the greatest amount of sonar information. F

ISH

A

LARM

, F

ISH

S

ENSITIVITY

, and

F

ISH

ID provide advanced signal processing to identify fish

and show their depth and relative size from either beam.

Powering Up the Unit

After installation, turn the L

EGEND

1000 S

ERIES

on by momentarily pressing the

G

AIN

knob. An audible chirp sounds as the unit turns on. If the unit detects

that the transducer is connected and is in water, the L

EGEND

1000 S

ERIES

begins to show sonar information on the display. If the transducer is not
detected, the unit starts up in S

IMULATOR

mode.

To power the unit off at any time, press and hold the G

AIN

knob for several

seconds until the unit turns off.

Simulator and Feature Memory

The L

EGEND

1000 S

ERIES

contains a

S

IMULATOR

that allows you to use the

unit as though you are on the water.
The S

IMULATOR

is an invaluable aid to

learning the features and functions of the L

EGEND

1000 S

ERIES

. All controls

are operational and settings can be changed to experiment with various
features. An indicator appears at the bottom left of the display when
operating in S

IMULATOR

mode.

There are two ways to start the S

IMULATOR

. The method to use depends on

whether a transducer is connected.

Power On with No
Transducer

If the L

EGEND

1000 S

ERIES

is powered

on with no transducer connected, it
starts up in S

IMULATOR

mode. No other

steps are needed. In this mode, the L

EGEND

1000 S

ERIES

does not

remember any setting changes after power off, but defaults to the factory
settings.

Power On with Transducer Connected

If the L

EGEND

1000 S

ERIES

is powered on with the transducer connected,

the S

IMULATOR

must be turned on manually. To turn on the S

IMULATOR

manually:

1. Press the Control Panel knob to display the list of

options.

2. Rotate the Control Panel knob to scroll through the list

until Simulator is visible and is highlighted on the
display.

3. Turn the Range knob to turn Simulator from Off to

On.

4. Press the Control Panel knob to clear the screen.

When operating with the Simulator on and the transducer connected,
changes made to the following Control Panel choices are permanently
remembered: Chart Speed, RTS Window, Surface Clutter, Contrast,
White Line, Units, and in International Models, Language.

USING THE LEGEND 1000 SERIES

PERFORMANCE / SIMULATOR / POWERING UP THE UNIT

Legend Models

4000 Watts Peak to Peak

International

*

North

American

Dual Beam
2' to 600'

Dual Beam
2' to 2000'

Single
Beam
2' to 600'

1000

2000

3000

3005

1000 Deep

2000 Deep

3000 Deep

1005 Deep

2005 Deep

3005 Deep

1005

2005

1000 Series

160 x 160 pixels

8 levels grayscale

2000 Series

240 x 240 pixels

16 levels grayscale

3000 Series

240h x 320v pixels
16 levels grayscale

Note: International models include multiple
languages and measurements in metres, feet
or fathoms. Temperature includes

°C.

2000 Series

Advertising