Using the legend 1000 series – Humminbird Legend 1000 User Manual

Page 9

Advertising
background image

In

A

UTOMATIC

mode, the

L

EGEND

1000 S

ERIES

selects the depth

range best suited to keep
recent sonar returns
visible; however, the depth
range can be adjusted to
optimize the display for
viewing the second return.
The display can also be
optimized for maximum
display resolution, making
it possible to distinguish fish very close together or close
to the bottom.

Optimizing the Depth Range for Sonar Targets
When the image of the bottom does not appear close
to the bottom of the LCD display, the Legend 1000
Series is not fully optimizing the display to show sonar
targets, such as fish, that are very close together. To
enhance the ability of the unit to separate sonar
targets and to optimize the display for maximum
resolution, follow these steps:

1. Make sure the Legend 1000 Series is operating in

Automatic Mode.

2. Push the

R

ANGE

knob. An adjustment indicator

appears at the lower right corner of the

C

HART

W

INDOW

.

3. Turn the

R

ANGE

knob counterclockwise until the image

of bottom is close to the bottom of the LCD display
but still shows the area of interest.

Note: As the depth of the water increases, the

L

EGEND

1000 S

ERIES

changes the depth range to keep the bottom on-screen. The

L

EGEND

1000 S

ERIES

uses a depth range to keep the bottom

contour close to the bottom of the display.

To return the depth range to normal viewing, turn the
unit off and back on again using the

G

AIN

knob. This is

the only way to reset the depth range to normal
viewing.

Optimizing the Depth Range for Second Return
To optimize the depth range for viewing the second
return, follow these steps.

1. Make sure the

L

EGEND

1000 S

ERIES

is operating in

Automatic.

2. Push the

R

ANGE

knob. An adjustment indicator

appears at the lower right corner of the

C

HART

W

INDOW

.

3. Turn the

R

ANGE

knob clockwise until the second return

is visible on the display.

4. To return the depth range to normal viewing, rotate

the

R

ANGE

knob counterclockwise until the depth

range stops updating.

Note: The second return does not appear at many of the deeper
depth ranges. The appearance of the second return depends
on depth of the water, water conditions, bottom hardness and
the gain setting.

The

L

EGEND

1000 S

ERIES

operates with this offset depth

range until it is returned to the original settings, or the
unit is turned off, after which the unit defaults to
factory settings.

7

USING THE LEGEND 1000 SERIES

MODES OF OPERATION / OPTIMIZING THE DISPLAY

Adjustment Indicator

Optimized Display

Optimized Display showing second return