Troubleshooting – haier 311209J User Manual

Page 10

Advertising
background image

Troubleshooting

10

311209J

Troubleshooting

.

Some solutions require disassembling gun. Always
relieve system pressure and disconnect electrical cable
before performing these procedures.

Problem

Cause(s)

Solution(s)

Material leaks from front of gun body Seat or packing is worn

Obstruction inside gun

Worn needle

Replace seat (6) or packing (47).

Remove seat (6). Check and replace
if necessary.

Check and replace needle (4a) if nec-
essary.

Material leaks from back of gun body Needle seal or packing is worn

Replace seals (4c) or packing (4d).

Gun does not shut off

Needle or seat is worn

Spring is broken or not installed cor-
rectly

Obstruction inside gun

Replace needle (4a) or seat (6).

Check and replace spring (14) if nec-
essary.

Remove seat (6). Check and replace
if necessary.

Gun does not heat material

Loose heater wires

Loose sensor wires

Heater cartridge failed

Sensor failed

Temperature controller failed

No power to heating circuitry

Check and reconnect wire connec-
tions.

Check and reconnect wire connec-
tions.

Replace failed heater.

Replace failed sensor.

Refer to Therm-O-Flow

®

200 manual

311208 as appropriate.

Advertising