Parallel port setup menu, Remote control – serial port, Preset – HHB comm UDP-89 User Manual

Page 43: Parallel, Profile 1, Profile 2, Not used, Input, Additional features

Advertising
background image

Additional Features

42

UDP-89 User Manual Version 2.1

www.hhb.co.uk

Parallel Port Setup Menu

The Parallel Port Setup menu is accessed by pressing the

SETUP button

on the front panel for longer than 0.5 second

while no disc is loaded (the front panel display should show

No Disc.) The front panel display will then show Parallel Preset.

Preset

Parallel

Profile 1

Parallel

Profile 2

Parallel

The Parallel Port provides for one factory default assignment

“memory” called Preset (see table on page 41), and two user-

definable assignable memories, Profile 1 and Profile 2. Preset
is not alterable. Pressing the LEFT or RIGHT cursor keys

will

step through the three memories.

SETUP

RIGHT CURSOR

LEFT CURSOR

PRESET

(DEFAULT)

PROFILE 1

PROFILE 2

Initially, the two Profile memories are empty. To assign

commands to the inputs, press MARK/ENTER

; the front

panel will display then show the current assignment to Input 1

(initially Not Used).

Not Used

P.

Input

1

The command to be assigned to Input 1 can be selected from

those available (see the first column in the Parallel Control

table on page 41) by stepping through the list with the UP or

DOWN cursor keys. It is not necessary to press MARK/ENTER

to confirm the assignment; when the required command is

displayed, the next input/output may be selected with the LEFT

or RIGHT cursor keys.

The Parallel Port outputs (tallies) may be assigned in the same

way; Output 1’s assignment will be displayed by a RIGHT cursor

key press from Input 5.

The default command set in the Preset memory may be

inspected in the same way, but the UP/DOWN cursor keys are

non-functional.

The Parallel Port Setup menu will automatically time-out if no

button is pressed for approx. 10 seconds; any changes to the

Profile memories will be saved at this time. Furthermore, the

UDP-89 will always “wake up” after a power-down with the last-

used Profile in use.

Remote Control – Serial Port

The rear panel RS232 Port provides serial control of virtually

every machine function, parameter and setting.

This section of the manual provides details of the port

parameters and an abridged serial command list, which includes

the main machine functions. The full RS232 protocol is beyond

the scope of this manual, but can be referenced or downloaded

as a .pdf file at www.hhb.co.uk.

Pinout

The rear panel connector is a D9M. The pinout is shown in the

table:

PIN

FUNCTION

1

Not used

2

Data receive

3

Data tramsmit

4

+5 v

5

0 v

6

Not used

7

RTS

8

CTS

9

Not used

Port parameters

PARAMETER

VALUE/SETTING

Data type

RS232C serial, 3-wire, half-duplex

Data speed

9600 baud

Word length

8 bits

Parity

None

Stop bits

One

Advertising