Specifications

Electrical

Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each.

Model

Icemaker

Dispenser

number

amperage

amperage

Single-sided models

U155, U155X

2.4 amps

U155B, U155BX

4.4 amps

U155R400A/W, U155R400A/WX

11.0 amps

2.4 amps

U155BR400A/W, U155BR400A/WX

11.0 amps

4.4 amps

U155R800A/W, U155R800A/WX

11.0 amps ea (2)

2.4 amps

U155BR800A/W, U155BR800A/WX

11.0 amps ea (2)

4.4 amps

Plumbing

Dispenser

3/4" PVC pipe nipple for bin drain

3/4" PVC pipe nipple for drain pan drain

1" ID hose for beverage bath drain

Beverage connections
1/4" ID syrup beverage hose

3/8" ID carbonated water beverage hose

3/8" ID plain water beverage hose

Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)

slope on drain line run.

Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.

Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected
to automatic fill dispensers.

Icemaker

(detailed specifications may be found in icemaker installation manual

packed with icemaker)

3/8" OD push-in water in

3/4" MPT drain

3/8" FPT condenser inlet (water-cooled condenser only)

1/2" FPT condenser drain (water-cooled condenser only)