Dimensions and clearances – Follett U155BX User Manual

Page 6

Advertising
background image

Dimensions and clearances

Required clearances

51" (1295mm) minimum above counter for installation if dispenser will be dropped into counter

36" (915mm) minimum above counter for all units after installation for auger cleaning and servicing

12" (305mm) minimum on side opposite ice chute for service

12" (305mm) minimum on ice chute side if ice transport tube enters this side

12" (305mm) minimum between dispenser side(s) and optional icemaker(s)

6

*DO NOT

CONNECT TO

DRAIN SYSTEM

6"

min

27.375"

(696mm)

ice transport

Side View

Front View

tube entrance

6"

(153mm)

25.8"

(656mm)

bin

signal

power

8.75"

(223mm)

3/4 PVC
slip joint
drain

3/4 PVC slip
joint drain

18.5"

(470mm)

beverage
waterbath
overflow

beverage
drain pan
drain

3.5"

(889mm)

37.25"

17"

(432 mm)

18.875"
(479mm)

18.875"
(479mm)

beverage line

air break*

electrical
connections

31.25"

(794mm)

21.75"

(553mm)

28"

(712mm)

counter top

ice
transport
tube

49.75"

(1264mm)

(8 valve unit)

(10 valve unit)

(947mm)

Manual load unit

Automatic load unit with 1 icemaker

Automatic load unit with 2 icemakers

12"

min