Battery life, Calibration, Scpi commands – Fluke STIK 1551A EX User Manual

Page 21: Rs-232 interface, Specifications, Xw warning

Advertising
background image

Stik Thermometer

SCPI Commands

13

Battery Life

Battery life is approximately 300 hours (12.5 days) of continuous operation with the
backlight off. A low-battery icon (

E) shows in the lower right of the display when

battery level is low. Replace batteries per recommendations found in the specifications
section of this manual.

Calibration

For calibration information, refer to the document on the documentation CD.

SCPI Commands

For a list of the SCPI commands, refer to the document on the documentation CD.

RS-232 Interface

An RS-232 interface is standard on the Product. Serial communication can be used for

configuration, calibration, and to move measurement data from the Product. An RS-232

cable is included with data logging software purchase.

XW

Warning

To prevent possible electrical shock, fire, or personal injury, the
RS-232 interface must not be used in hazardous areas.

Specifications

(Ambient: 23

°

C

±

5

°

C)

Measurement Range

1551A

Ex

.........................................................................

50

°

C to 160

°

C (

58

°

F to 320

°

F)

1552A

Ex

.........................................................................

80

°

C to 300

°

C (

112

°

F to 572

°

F)

Accuracy (1 year) .....................................................................

±

0.05

°

C (0.09

°

F)

Resolution ................................................................................. Selectable (0.1, 0.01, 0.001) factory default is 0.01
Sample Rate ............................................................................. User selectable 0.5/sec, 1/sec or 2/sec factory default is

1/sec

Operating Temperature Range of Readout: ..........................

10

°

C to 50

°

C (14

°

F to 122

°

F)

Probe Response Time .............................................................. Approximately 20 seconds
EMC Compliance....................................................................... EN61326:2006 Annex C

CISPR 11, Edition 5.0-2009

Class

“B”

Humidity Range......................................................................... 0 to 95 % RH Non-condensing

Storage Temperature Range....................................................

20

°

C to 60

°

C (

4

°

F to 140

°

F)

Enclosure Rating ...................................................................... IP50

Readout Temperature Coefficient ........................................... Add

±

10 ppm/

°

C of full scale temperature from

10

°

C to

18

°

C and 28

°

C to 50

°

C

Probe Temperature Coefficient .............................................. 0.00385

Ω

/

Ω

/

°

C nominal

Nominal Probe Resistance at 0

°

C .......................................... 100

Ω

Probe Hysteresis.......................................................................

±

0.01

°

C

Power ......................................................................................... 3 AAA alkaline batteries

(Must use only approved batteries. See Table 2)