Unpacking mobile home installation – FRIGIDAIRE 134897500B User Manual

Page 7

Advertising
background image

7

PLASTIC SPACER
BLOCK

MECHANISM
SHIPPING
BOLT

FOAM
SHIPPING
PAD

DRAIN HOSE

POWER CORD
(IF EQUIPPED)

SHIPPING CARTON CORNER POSTS

1. Using the four shipping carton corner posts (two on each

side), carefully lay the laundry center on its left side and
remove foam shipping base.

CAUTION

Excessive weight. Use two or more

people to move Laundry Center.

2. Using a ratchet with 3/8 inch (0.96 cm) socket, remove the

mechanism shipping bolt and plastic spacer block from the
center of the base.

NOTE: If the laundry center is to be transported at a later
date, the tub blocking pad, shipping bolt, and plastic
spacer block should be retained.

3. Return laundry center to an upright position.

4. Remove:

(a) foam tub blocking pad.
(b) tape from dryer door.
(c) foam dryer support pads.
(d) inlet hoses.
(e ) enclosure package.

5. From the back of the washer, remove the wire shipping clips

securing the drain hose and power cord (if equipped).
Plastic clamps secure the drain hose to the right side of the
washer backsheet. These clamps form a standpipe to prevent
water syphoning. DO NOT REMOVE THESE CLAMPS.

6. Carefully move the laundry center to within 4 feet (1.22 m)

of the final location to begin the installation.

1.Dryer MUST be exhausted outside (outdoors, not beneath the mobile

home) using metal ducting that will not support combustion. Metal
ducting must be 4 inches (10.16 cm) in diameter with no obstructions.
Rigid metal duct is preferred.

2.If dryer is exhausted through the floor and area beneath the mobile

home is enclosed, the exhaust system MUST terminate outside the
enclosure with the termination securely fastened to the mobile home
structure.

3.Refer to page 4 for other important venting requirements.

4.When installing a gas dryer into a mobile home, a provision must be

made for outside make up air. This provision is to be not less than twice
the area of the dryer exhaust outlet.

5.Installation MUST conform to current Manufactured Home Construction

& Safety Standard (which is a Federal Regulation Title 24 CFR-Part 32-
80) or when such standard is not applicable, with American National
Standard for Mobile Homes. In Canada, the CSA Z240 is applicable.

WARNING

The laundry center is designed under ANSI Z 21.5.1for HOME USE only.

UNPACKING

MOBILE HOME INSTALLATION