NON-CANADIAN ELECTRIC Laundry Center

5. Attach the remaining two power cord outer conductors to

the outer brass colored terminals on the terminal block.
Tighten both screws securely.

6. Tighten the screws securing the cord restraint against the

power cord.

7. Reinstall the terminal access cover.

SILVER TERMINAL

GREEN GROUND SCREW

NEUTRAL
GROUND
WIRE

ELECTRICAL CONNECTIONS

FOR A 3-WIRE SYSTEM

1. Remove the screw securing the

terminal block access cover to
the rear panel and remove cover.

2. Install a U.L. approved strain

relief connector in the entry
hole on the back panel.

3. Insert a NEMA 10-30 Type SRDT,

U.L. approved power cord through the strain relief.

4. Attach the power cord neutral (central wire) conductor to

the silver colored center terminal on the terminal block.
Tighten the screw securely.

NON-CANADIAN ELECTRIC Laundry Center

NEUTRAL
GROUND
WIRE

1. Remove the screw securing the

terminal block access cover to the
rear panel and remove cover.

2. Install a U.L. approved strain relief

connector in the entry hole on the
back panel.

3. Remove the neutral ground wire from the green ground

screw located above the termial block.

4. Insert a NEMA 14-30 Type ST or SRDT, U.L. approved power

cord through the strain relief.

5. Attach the green power cord ground wire to the cabinet

with the green ground screw.

6. Attach the white (neutral) wire from the power cord and the

neutral ground wire from the appliance harness to the silver
colored center terminal on the terminal block. Tighten the
screw securely.

7. Attach the red and black wires from the power cord to the

outer brass-colored terminals on the terminal block. Tighten
both screws securely.

8. Tighten the screws securing the cord restraint firmly against

the power cord.

9. Reinstall the terminal block access cover.

ELECTRICAL CONNECTIONS

FOR A 4-WIRE SYSTEM