Specifications

47

Table 15. Capacitance and Diode Function Specifications

Function

Range

Resolution

Accuracy

1

E

5.00 nF
0.0500

µ

F

0.500

µ

F

5.00

µ

F

0.01 nF
0.0001

µ

F

0.001

µ

F

0.01

µ

F

±

(1% + 3)

±

(1% + 3)

±

(1% + 3)

±

(1.9% + 3)

G

3.000 V

0.001 V

±

(2% + 1)

1.

With a film capacitor or better, using Relative mode to zero residual. See the first sentence in Table 11 for a complete explanation of
accuracy.

Table 16. Frequency Counter Specifications

Function

Range

Resolution

Accuracy

1

Frequency

(0.5 Hz to 200 kHz,

pulse width >2

µ

s)

199.99

1999.9

19.999 kHz

199.99 kHz

>200 kHz

0.01 Hz

0.1 Hz

0.001 kHz

0.01 kHz

0.1 kHz

±

(0.005% + 1)

±

(0.005% + 1)

±

(0.005% + 1)

±

(0.005% + 1)

unspecified

1.

See the first sentence in Table 11 for a complete explanation of accuracy.