4-5

7. Wire cable assembly as shown in the figure below.

Reattach this tape as
shown right after the
DGPS connection.

To J8 of
ANLG Board

GN-7707

J1

GR-7000A

J2

J3

Connector
PH6P-W-L240

J2

Figure 4-6 Wiring the Cable assembly

8. Mount the ANLG board on the heat sink referring to step 2. Fasten cable assy.

S.FL2-2LP0.7-D-WHT (250), 8P connector cable and 6P connector cable by
cable tie (CV-100, supplied) as shown in the figure below. Fix cable assy. S.FL2-
2LP0.7-D-WHT (250) with vinyl tape.

J8

ANLG Board

6P connector

GN-7707

Cable
tie

8P connector

40 to 45 mm

10 mm

10 mm

MAIN Board

40 to 45 mm

vinyl tape

Figure 4-7 Attaching cable tie

9. Connect J1 of GR-7000A to J8 of ANLG board (Refer to Figure 4-6).

10.Mount chassis assembly on the panel assembly. Connect 8P connector and 6P

connector to Main board as shown in Figure 4-8.