4

RS-232C external control

2-3 Parameters used for the data format

The following three kinds of parameters are prepared for the control command and response data.

(1) Numeric value

Designates the 2-byte hexadecimal value with the sign as the 4-digit (byte) characters.
Designation allowable range: “8000” to “7FFF”

(2) ON/OFF

Designates the status (ON/OFF) of the projector, such as POWER and HIDE.

(3) Special parameters

Input switching parameters:

Operation mode parameters:

3. Control command table

The control commands that can be sent from the computer are as follows:

* Keystone: Numeric value can range from “FF80” to “0080”
* Operation mode: Only Asking command is possible

Character

Hex.

Meaning

“0”

30

OFF

“1”

31

ON

Character

Hex.

Meaning

“0”

30

Y/C

“1”

31

VIDEO

“2”

32

COMP

“3”

33

PC1

“4”

34

PC2

“5”

35

DVI

Character

Hex.

Meaning

“0000”

30h, 30h, 30h, 30h

Stand-by mode

“0001”

30h, 30h, 30h, 31h

Power-on mode

“0002”

30h, 30h, 30h, 32h

Cool-down mode

“0004”

30h, 30h, 30h, 34h

Warning mode

Function

Command

Asking

Kind of data

Power ON

ELSE

Numeric Value

ON/OFF

Special Data

OPERATE

U0F

HIDE

U00

Right Left rev.

U17

Top Bottom inv.

U18

Keystone

U40

Input

U1A

Y/C, VIDEO, PC1, PC2,
COMP, DVI

Operation mode

Z03

Stand-by, Power-on,
Cool-down, Warning