1 portable filter pump fails to pump oil – Frymaster Electric Fryer User Manual

Page 21

Advertising
background image

20

9.5.1 Portable Filter Pump Fails to Pump Oil?

Does

your filter have a

heater?

Turn heater "ON"

and run heater

for 15 minutes.

Does oil

flow?

Conduct normal

filter operations.

Can you

blow air through

Insert flexible oil return

hose into the filter pan

holster. Turn pump

motor "ON".

Does oil

flow?

Blockage is between

the bottom of the filter

pan and the flex hose

valve. Go to page 22.

Yes

No

Yes

No

No

it?

Yes

Yes

No

Insert flexible oil return
hose into the filter pan
holster. Turn pump
motor "ON".

Disconnect flexible oil
return hose. Make sure it
is cool before handling.
Try blowing air through it.

Submerge hose into hot water over
49°C (120°F). Keep both ends out
of the water. If water gets into the
hose, the water will cause severe
splattering when hose is
reconnected to the filter.

Once shortening has
softened, reconnect the
flexible oil return hose
to the filter.

Filter Pump fails

to pump oil.

Advertising