3 blockage between filter pan and flex hose valve, Heater troubleshooting pump troubleshooting – Frymaster Electric Fryer User Manual

Page 23

Advertising
background image

22

9.5.3 Blockage between Filter Pan and Flex Hose Valve?

Blockage has been

determined to be between

the filter pan bottom and

the flex hose valve.

Does your

filter have a

heater?

Disconnect oil line from the

filter pan to the pump at the

pump end.

Put finger over the inlet

connection to the pump.

Turn the pump "ON".

Does the pump

motor run?

Do you feel

suction?

Pump is clear of any

blockages. Go to Page

23 and continue.

Pump motor is clogged or

faulty.

Contact your local

Factory Authorized

Service Center.

Check filter circuit breaker.

Push the circuit breaker

reset button.

Verify power cord is

connected to the outlet.

Turn the

heater "ON". Does

the suction line feel

warm?

The heater is working

properly.

Turn the heater "OFF".

Check wall circuit

breaker.

If wall circuit breaker has

tripped, turn heater "OFF".

Reset wall circuit breaker.

Turn heater "ON".

If the suction line fails to

warm, the heater is faulty.

Contact your local

Factory Authorized

Service Center!

No

Yes

Yes

No

Yes

No

Yes

No

Heater
Troubleshooting

Pump
Troubleshooting

Advertising