Frymaster H50 Series User Manual

Page 13

Advertising
background image

1-7

Gas

Single

Vat

Dual

Vat

Natural Gas Lacq
(G20) under 20 mbar

7

7

Natural Gas Gronique *
(G25) under 25 mbar

10

10

Natural Gas Gronique
(G25) under 20 mbar

10

10

Butane/Propane
(G30) at 28/30 or 50 mbar

17

17

Propane
(G31) under 37 or 50 mbar

20

20

CE Standard

Burner Manifold Gas Pressures

for Fryers Manufactured After April 1999

Pressure (mbar)

* Belgian G25 = 7,0 mbar (single or dual)

Gas

Single

Vat

Dual

Vat

Natural Gas Lacq
(G20) under 20 mbar

7

6,5

Natural Gas Gronigue *
(G25) under 25 mbar

10

9

Natural Gas Gronigue
(G25) under 20 mbar

10

9

Butane
(G30) at 28/30 or 50 mbar

17

16,5

Propane
(G31) under 37 or 50 mbar

20,2

18,5

CE Standard

Burner Manifold Gas Pressures

for Fryers Manufactured Through April 1999

Pressure (mbar)

* Belgian G25 = 7,0 mbar (single) or 6,5 (dual)

Gas

Pressure

Natural

3" W.C.

0.73 kPa

Propane

8.25" W.C.

2.5 kPa

Non-CE Standard

Burner Manifold Gas Pressures

5. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the

correct pressure.

Non-CE

Valve

Earlier Model CE Valve

Later Model

CE Valve

GAS VALVE REGULATOR CAP

6. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove

the fitting from the pressure tap hole and reinstall the pressure tap plug.


Advertising