2.12.4 FMH50 Full Vat (1¼-inch) Valve Assembly
NOTES: Compression washers must
be turned face to face and lock nut
(Item 5) must be torqued to 80 ± 10
inch-pounds.
Item 11 does not come with assembly
806-8791SP.
1
Plastic Washer
(part of Item 1)
11
3
2
7
4
5
8
10
9
806-8791SP
Compression Washers
(part of Item 1)
6
Steel Flat Washer
(part of Item 1)
ITEM
PART #
COMPONENT
806-8791SP
Complete Assembly (does not include Item 11)
1
810-1020
Drain Valve, 1¼-inch NPT Inlet, 1-inch NPT Outlet
810-1018
Drain Valve, 1 ¼-inch, for Hybrid Units, Single FP and Jack in the Box FM.
2
900-2521
Handle, Drain Valve
3
814-0047
Sleeve, Red Valve Handle
4
900-2936
Retainer, ½-inch Nut
5
809-0540
Nut, 2-way Lock, ½–13
6
806-8137
Bracket, Drain Valve Microswitch
7
816-0220
Insulation, RF Switch
8
807-2103
Microswitch, Lever Activated
9
900-2841
Cover, Drain Safety Switch
10
826-1366
Nut, Keps, 4–40, w/external teeth (Pkg. of 25)
11
900-2354