From
Detergent
Reservoir

To Detergent
Outlet

Pump
Housing

Impeller

1

2

3

4

1

33

41

49

57

2

35.4

43.4

51.4

59.4

3

37.8

45.8

53.8

61.8

4

40.2

48.2

56.2

64.2

5

42.6

50.6

58.6

66.6

Smart Dispense Bottle Duration

1

2

3

4

1

10.3

8.3

6.9

5.9

2

9.6

7.8

6.6

5.7

3

9.0

7.4

6.3

5.5

4

8.4

7.0

6.0

5.3

5

8.0

6.7

5.8

5.1

Dosage (ml)

Har

d

ness

Soil Level

Hard

n

ess

Bottle Duration (wks)

Soil Level

Smart Dispense Dosage Amount

Positive Displacement Pump

The SmartDispense

TM

positive displacement pump

consists of a continuous fl exible tube running from
the detergent reservoir to the inner door detergent
outlet. The tube runs around the inside edge of the
pump housing. A 3-roller impeller fi ts tightly into
the center of the pump housing with each of the
3 rollers squeezing the sidewall of the tube. As the
impeller is driven counterclockwise by the motor, it
squeezes out a predetermined amount of detergent
for each 1/3 revolution of the impeller.

The dispenser pump operates on 120 VDC. During
each pre-wash cycle, the pump is energized for 5
seconds, dispensing 4ml of detergent.

The electronic control uses two inputs to determine
the total amount of detergent dispensed during the
main wash cycle:

• Soil Level determined by the turbidity sensor
• Water Hardness as calibrated for the location

A water hardness selection mode permits the
calibration of the water hardness for the location
at installation. (See

Water Hardness Test and

Calibration

.)

To determine the amount of detergent to dispense
during the main wash, the control uses the following
formula:

4ml x Number of Pre-washes

+ 25ml + Additional Quantity for Hardness

The additional quantity is a predefi ned quantity
of detergent based on the water hardness level
programmed into the control.

Approximate Detergent Use

To remove the pump

Remove the door panel. (See

Door Panel

.)

Remove 2 Phillips head screws from the lower
right side of the door edge to release the pump
bracket.

Remove the grommet from the inner door panel
and unplug the tube from the reservoir outlet.

Disconnect the wires and remove the pump.

Positive Displacement Pump Strip Circuit

ORANGE

BULK DETERGENT

PUMP

J2-1

M

WHITE